
Add to Cart
50HZ R410a 24000BTU Stand Type Air Conditioner QA Panel Split Ac Floor Stand
QA Stand-Type Panel Inverter 220V R410a 24000BTU Cooling Heating High Quality Wifi Control PCB 3 Year Warranty
Dehumidification
The air conditioner is accompanied by dehumidification during the refrigeration process. The relative humidity of the environment that people feel comfortable should be around 40-60%. When the relative humidity is too high, such as above 90%, even if the temperature is within a comfortable range, people still feel bad.
Purifying air
The air contains a certain amount of harmful gases such as NH3, SO2, etc., as well as various odors such as sweat, body odor and bathroom odor.
Technical Specifications | |||
24K | |||
Type | heating pump | ||
Control type | remote | ||
Rated cooling capacity | Btu/h | 15695 | |
W | 4600 | ||
Rated heating capacity | Btu/h | 17674 | |
W | 5180 | ||
EER for cooling | W/W | 2.4 | |
COP for heating | W/W | 2.64 | |
Moisture removal | Liters/h | 1.99 | |
Pressure | High(DP) | MPa | 2.6 |
Low(SP) | MPa | 1 | |
Indoor noise level at cooling | SUPER | dB(A) | 45 |
High | dB(A) | 42 | |
Med | dB(A) | 39 | |
Low | dB(A) | 36 | |
MUTE | dB(A) | 36 | |
Outdoor noise level | dB(A) | 58 | |
Electrical Data | |||
Power supply | 220-240V/50Hz | ||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 9.8 |
Heating | A | 9.5 | |
Rated input | Cooling | W | 2042 |
Heating | W | 1958 | |
Max Current | Cooling | A | 13.5 |
Heating | A | 11.7 | |
Max Power input | Cooling | W | 2472 |
Heating | W | N.A | |
Refrigerating System | |||
Refrigerant/Charge | Gram | R410A | |
Compressor | Model | / | |
MFG | / | ||
Type | Rotary | ||
Connections | |||
Connecting Pipe | Gas | Inches | Φ12(1/2'') |
Liquid | Inches | Φ6(1/4'') | |
Connecting Wiring | Size x Core number | 5*1.5 | |
Drainage Pipe | O.D 16mm | ||
Others | |||
Suitable area | m2 | 20~30 | |
Net dimensions (W x H x D) | Indoor | mm | |
Outdoor | mm | ||
Net weight | Indoor | kg | 13 |
Outdoor | kg | 39 | |
Packing dimensions (W x H x D) | Indoor | mm | 420*420*1800mm |
Outdoor | mm | 870×321×590 870*340*590 | |
Gross weight) | Indoor | kg | 14 |
Outdoor | kg | 49/40 | |
Loading Capacity w/i pipe | 40'HQ | 262/250 |
Precautions
- The indoor temperature cannot be adjusted too low, otherwise it is harmful to the human body, so the set temperature should be adjusted appropriately.
- If you feel the room temperature is too high, you can appropriately lower the set temperature.
Effective use of timers can achieve both energy-saving and comfortable effects.
- There should not be too many people or overcrowding in the air-conditioned room, otherwise the cooling capacity will be insufficient and the temperature will not drop;
- Doors and windows of the room should not be opened and closed frequently, and personnel should not enter and exit frequently to avoid loss of air-conditioning;
- The glass windows must be closed and tightly closed, and double white curtains must be hung inside to reflect part of the light and heat that penetrates;
- The window can be opened for a short time during indoor ventilation, and the window opening time is generally no more than 10 minutes
- The air filter should be cleaned regularly, otherwise the air flow will be blocked, resulting in insufficient air volume and increased room temperature
- To adjust the temperature during sleep, the air conditioner can automatically adjust the sleep temperature