Add to Cart
R410A 9000 Btu DC Wall Mounted Air Conditioner And Heater Combo
YC Panel R410A Wall AC 50hz 220V 9000Btu DC Air Conditioner Cooling heating Wifi Control PCB 3 year machinery warranty
Wall-mounted air conditioners are widely welcomed by everyone, and the technology is constantly innovating. You should pay attention to comparing the functional differences of each brand.
The ventilation function is the latest technology used in wall-mounted air conditioners to ensure that there is fresh air in the home, prevent the occurrence of air-conditioning diseases, and make it more comfortable and reasonable to use.
In addition, quiet and energy-saving designs are also very important, allowing you to sleep peacefully until dawn. Some wall-mounted air conditioners have ultra-small outdoor units. If you plan to put the outdoor units on the balcony, this is also a good choice.
9000BTU | |||
Model No. | YTA-09CH | ||
KFR-25GW | |||
indoor 770(Φ7.94×1)+outdoor700(Φ7.94×1) | |||
Type | Heating Pump | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 8048;2359 | |
Rated heating capacity | Btu/h;W | 8632;2530 | |
EER for cooling | Btu/h.w; W/W | 2.48 | |
COP for heating | W/W | 2.7 | |
Moisture removal | Liters/h | 0.78 | |
Pressure | High(DP) | MPa | 2.8 |
Low(SP) | MPa | 1.2 | |
Indoor noise level at cooling | High | dB(A) | 39 |
Med. | dB(A) | 34 | |
Low | dB(A) | 22 | |
Outdoor noise level | dB(A) | 49 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 4.4 |
Heating | A | 4 | |
Rated input | Cooling | W | 947 |
Heating | W | 936 | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 7.09 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1337 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R22 | |
Compressor | Type | Rotary | |
Model | 凌达QX-B160C130 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 430/430 | |
Indoor fan type | Cross flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1160/1060/900 |
Heating | rpm | 1160/1060/900 | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 8 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ9 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*0.75 | |
Drainage Pipe | |||
Suitable area | m2 | 8~12 | |
Net dimensions (W x H x D) | Indoor | mm | 770x250x205 |
Outdoor | mm | 700x540x255 | |
Net weight | Indoor | kg | 9 |
Outdoor | kg | 30 | |
Packing dimensions (W x H x D) | Indoor | mm | 840*279*325 |
Outdoor | mm | 815*350*600 | |
Gross weight | Indoor | kg | 10 |
Outdoor | kg | 34 |
3 Year for machinery warranty,1 year for core conponents.
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part
Maintenance
Maintenance before starting up
Generally, household air conditioners are turned off in September and then turned on from May to June of the following year. They will not be used for more than half a year. Therefore, a comprehensive "diagnosis" must be done before the air conditioner is turned on to check whether the air conditioner is "faulty". According to the results of the inventory, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning. This time, the maintenance and cleaning should be more in place. Including the casing, body, and filter of the outdoor unit and the indoor unit, and then start trial operation to observe the cooling speed and effect.