Generally, it includes cold source/heat source equipment, cold and hot medium transmission and distribution system, terminal equipment and other auxiliary equipment. It mainly includes refrigeration host, water pump, fan and piping system. The terminal device is responsible for using the cold and heat from the transmission and distribution to specifically process the air condition so that the air parameters of the target environment meet certain requirements.
12000BTU | |||
Model No. | TAC-12CS/Z | ||
KF-35GW | |||
indoor 820(Φ7×2)+outdoor 780(Φ7.94×1) | |||
Type | cooling only | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 11535;3381 | |
Rated heating capacity | Btu/h;W | N.A | |
EER for cooling | Btu/h.w; W/W | 2.7 | |
COP for heating | W/W | N.A | |
Moisture removal | Liters/h | 1.3 | |
Pressure | High(DP) | MPa | 2.6 |
Low(SP) | MPa | 1 | |
Indoor noise level at cooling | High | dB(A) | 41 |
Med. | dB(A) | 37 | |
Low | dB(A) | 24 | |
Outdoor noise level | dB(A) | 52 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 5.8 |
Heating | A | N.A | |
Rated input | Cooling | W | 1253 |
Heating | W | N.A | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 9.8 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1790 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R410A/R22 | |
Compressor | Type | Rotary | |
Model | 三洋C-RV212H92CB/凌达QX-B217E030A | ||
LRA | A | / | |
MFG | SANYO/GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 530 | |
Indoor fan type | Cross Flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1290/1150/900 |
Heating | rpm | N.A | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 13 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ12 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 1.0*3 | |
Drainage Pipe | |||
Suitable area | m2 | 12~23 | |
Net dimensions (W x H x D) | Indoor | mm | 820x250x205 |
Outdoor | mm | 780x540x255 | |
Net weight | Indoor | kg | 10 |
Outdoor | kg | 31 | |
Packing dimensions (W x H x D) | Indoor | mm | 890*279*325 |
Outdoor | mm | 870*340*590 | |
Gross weight | Indoor | kg | 12.5 |
Outdoor | kg | 37 |
The structure of the air conditioner includes: compressor, condenser, evaporator, four-way valve, one-way valve capillary assembly, etc.
Dehumidification
The air conditioner is accompanied by dehumidification during the refrigeration process. The relative humidity of the environment that people feel comfortable should be around 40-60%. When the relative humidity is too high, such as above 90%, even if the temperature is within a comfortable range, people still feel bad.
Purifying air
The air contains a certain amount of harmful gases such as NH3, SO2, etc., as well as various odors such as sweat, body odor and bathroom odor.
Purification methods for air conditioners include: changing fresh air, filtering, and using activated carbon or photocatalyst to absorb and absorb.