ISO Approved 50HZ 220V Wall Mounted Air Cond R410a R32 18000BTU
QA Panel 50HZ 220V R410a/R32 18000BTU Cooling Heating High Quality Wifi Control PCB 3 Year Warranty
18000BTU | |||
Model No. | TAC-18CHS/Z | ||
KFR-48GW | |||
indoor860(Φ7×2)+outdoor820(Φ7.94×2) | |||
Type | Heating Pump | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 15695;4600 | |
Rated heating capacity | Btu/h;W | 17674;5180 | |
EER for cooling | Btu/h.w; W/W | 2.4 | |
COP for heating | W/W | 2.64 | |
Moisture removal | Liters/h | 1.99 | |
Pressure | High(DP) | MPa | 2.6 |
Low(SP) | MPa | 1 | |
Indoor noise level at cooling | High | dB(A) | 42 |
Med. | dB(A) | 39 | |
Low | dB(A) | 36 | |
Outdoor noise level | dB(A) | 58 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 9.8 |
Heating | A | 9.5 | |
Rated input | Cooling | W | 2042 |
Heating | W | 1958 | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 13.5 |
Heating | A | 11.7 | |
Max Power input | Cooling | W | 2472 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R410A/R22 | |
Compressor | Type | Rotary | |
Model | QX-D336F030 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 800/850 | |
Indoor fan type | Cross flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1300/1140/980 |
Heating | rpm | 1300/1140/980 | |
Dry | rpm | 980 | |
Sleep | rpm | 980 | |
Indoor fan motor output | W | 18 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 45 | |
Connecting Pipe | Gas | mm | Φ12 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*1.5 | |
Drainage Pipe | |||
Suitable area | m2 | 20~30 | |
Net dimensions (W x H x D) | Indoor | mm | 860*299*190 |
Outdoor | mm | 820*600*300 | |
Net weight | Indoor | kg | 13 |
Outdoor | kg | 39 | |
Packing dimensions (W x H x D) | Indoor | mm | 910*365*265mm |
Outdoor | mm | 920*405*645 | |
Gross weight | Indoor | kg | 15.5 |
Outdoor | kg | 41/42 |
Precautions
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;