Cooling Onlying Wall Mounted AC Unit 9000 Btu Air Conditioner 50HZ 220V
QA Panel 50HZ 220V R410a/R22 9000BTU Cooling Onlying High Quality Wifi Control PCB 3 Year Warranty
Precautions
- To adjust the temperature during sleep, the air conditioner can automatically adjust the sleep temperature
- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;
- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;
When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;
- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;
- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged
9000BTU | |||
Model No. | YTA-09C | ||
KF-26GW | |||
indoor 760(Φ7.94×1)+outdoor700(Φ7.94×1) | |||
Type | cooling only | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 8048;2359 | |
Rated heating capacity | Btu/h;W | N.A | |
EER for cooling | Btu/h.w; W/W | 2.48 | |
COP for heating | W/W | N.A | |
Moisture removal | Liters/h | 0.78 | |
Pressure | High(DP) | MPa | 2.8 |
Low(SP) | MPa | 1.2 | |
Indoor noise level at cooling | High | dB(A) | 39 |
Med. | dB(A) | 34 | |
Low | dB(A) | 22 | |
Outdoor noise level | dB(A) | 49 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 4.4 |
Heating | A | N.A | |
Rated input | Cooling | W | 947 |
Heating | W | N.A | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 7.09 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1337 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R410A/R22 | |
Compressor | Type | Rotary | |
Model | 凌达QX-B160C130 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 430 | |
Indoor fan type | Cross Flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1160/1060/900 |
Heating | rpm | N.A | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 8 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ9 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*0.75 | |
Drainage Pipe | |||
Suitable area | m2 | 8~12 | |
Net dimensions (W x H x D) | Indoor | mm | 760*299*190 |
Outdoor | mm | 700x540x255 | |
Net weight | Indoor | kg | 8.5 |
Outdoor | kg | 28 | |
Packing dimensions (W x H x D) | Indoor | mm | 840*279*325 |
Outdoor | mm | 815*350*600 | |
Gross weight | Indoor | kg | 10 |
Outdoor | kg | 34 |
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part