CA Panel Cooling Heating Wall Mounted AC Unit 60HZ 220V R410a R22 9000BTU
CA Panel 60HZ 220V R410a/R22 9000BTU Cooling Heating High Quality Wifi Control PCB 3 Year Warranty
When the inverter air conditioner is in operation, the high frequency operation temperature rises first. When the room temperature reaches the set temperature of the air conditioner, the air conditioner becomes low frequency operation and keeps warm without shutting down. The power consumption of continuous low-frequency operation is only one-third or even one-fourth of the rated power. The same goes for refrigeration.
Inverter air conditioners do not have electric auxiliary heating elements that consume a lot of electricity.
To sum up, the continuous low-frequency operation of inverter air conditioners has neither frequent start-up inrush current nor long-term high-power operation like fixed-speed air conditioners, and there is no electric auxiliary heating element that consumes electricity. Therefore, inverter air conditioners are better than fixed-speed air conditioners. Speed air-conditioning saves energy and electricity.
9000BTU | |||
Model No. | YTA-09CH | ||
KFR-25GW | |||
indoor 770(Φ7.94×1)+outdoor700(Φ7.94×1) | |||
Type | Heating Pump | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 8048;2359 | |
Rated heating capacity | Btu/h;W | 8632;2530 | |
EER for cooling | Btu/h.w; W/W | 2.48 | |
COP for heating | W/W | 2.7 | |
Moisture removal | Liters/h | 0.78 | |
Pressure | High(DP) | MPa | 2.8 |
Low(SP) | MPa | 1.2 | |
Indoor noise level at cooling | High | dB(A) | 39 |
Med. | dB(A) | 34 | |
Low | dB(A) | 22 | |
Outdoor noise level | dB(A) | 49 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 4.4 |
Heating | A | 4 | |
Rated input | Cooling | W | 947 |
Heating | W | 936 | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 7.09 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1337 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R22 | |
Compressor | Type | Rotary | |
Model | QX-B160C130 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 430/430 | |
Indoor fan type | Cross flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1160/1060/900 |
Heating | rpm | 1160/1060/900 | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 8 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ9 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*0.75 | |
Drainage Pipe | |||
Suitable area | m2 | 8~12 | |
Net dimensions (W x H x D) | Indoor | mm | 770x250x205 |
Outdoor | mm | 700x540x255 | |
Net weight | Indoor | kg | 9 |
Outdoor | kg | 30 | |
Packing dimensions (W x H x D) | Indoor | mm | 830*268*316 |
Outdoor | mm | 805*340*590 | |
Gross weight | Indoor | kg | 10 |
Outdoor | kg | 32 | |
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body, which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part